Caution, Sl-vf, Sl-vh – KEYENCE SL-V Series User Manual
Page 140
![background image](/manuals/658044/140/background.png)
7-4
Dimensions (SL-VF/VH/VL)
7-12
S
7
SL-V-M-NO7-E
When using two or more mounting brackets, be sure to install them so that the distance
between the centers of the mounting brackets does not exceed 600 mm in order to meet
"Vibration" and "Shock" in the specifications.
SL-VF
Units: mm
SL-VH
Units: mm
*1 Only one mounting bracket can be installed on the SL-V08H.
When mounting only with the E-to-E bracket or the compact E-to-E bracket
Caution
Model
Beam
axes
A:
Length
B:
Detection
height
C:
Protection
height
D:
Beam
axis
pitch
E
F
G: Intermediate support bracket mounting position
1st
2nd
3rd
4th
5th
6th
SL-V23F
23
230
220
244
10
5
12
70
±
10
140
±
10 Not needed Not needed Not needed Not needed
SL-V31F
31
310
300
324
70
±
10
220
±
10 Not needed Not needed Not needed Not needed
SL-V39F
39
390
380
404
70
±
10
300
±
10 Not needed Not needed Not needed Not needed
SL-V47F
47
470
460
484
70
±
10
380
±
10 Not needed Not needed Not needed Not needed
SL-V55F
55
550
540
564
70
±
10
460
±
10 Not needed Not needed Not needed Not needed
SL-V63F
63
630
620
644
70
±
10
540
±
10 Not needed Not needed Not needed Not needed
SL-V71F
71
710
700
724
70
±
20 340
±
100 620
±
20 Not needed Not needed Not needed
SL-V79F
79
790
780
804
70
±
20 380
±
100 700
±
20 Not needed Not needed Not needed
SL-V87F
87
870
860
884
70
±
20 420
±
100 780
±
20 Not needed Not needed Not needed
SL-V95F
95
950
940
964
70
±
20 460
±
100 860
±
20 Not needed Not needed Not needed
SL-V103F
103
1030
1020
1044
70
±
20 500
±
100 940
±
20 Not needed Not needed Not needed
SL-V111F
111
1110
1100
1124
70
±
20 540
±
100 1020
±
20 Not needed Not needed Not needed
SL-V119F
119
1190
1180
1204
70
±
20 410
±
100 750
±
100 1100
±
20 Not needed Not needed
SL-V127F
127
1270
1260
1284
70
±
20 440
±
100 810
±
100 1180
±
20 Not needed Not needed
Model
Beam
axes
A:
Length
B:
Detection
height
C:
Protection
height
D:
Beam
axis
pitch
E
F
G: Intermediate support bracket mounting position
1st
2nd
3rd
4th
5th
6th
SL-V08H
*1
8
150
140
185
20
5
22.5
60
±
10 Not needed Not needed Not needed Not needed Not needed
SL-V12H
12
230
220
265
70
±
10
140
±
10 Not needed Not needed Not needed Not needed
SL-V16H
16
310
300
345
70
±
10
220
±
10 Not needed Not needed Not needed Not needed
SL-V20H
20
390
380
425
70
±
10
300
±
10 Not needed Not needed Not needed Not needed
SL-V24H
24
470
460
505
70
±
10
380
±
10 Not needed Not needed Not needed Not needed
SL-V28H
28
550
540
585
70
±
10
460
±
10 Not needed Not needed Not needed Not needed
SL-V32H
32
630
620
665
70
±
10
540
±
10 Not needed Not needed Not needed Not needed
SL-V36H
36
710
700
745
70
±
20
340
±
100 620
±
20 Not needed Not needed Not needed
SL-V40H
40
790
780
825
70
±
20
380
±
100 700
±
20 Not needed Not needed Not needed
SL-V44H
44
870
860
905
70
±
20
420
±
100 780
±
20 Not needed Not needed Not needed
SL-V48H
48
950
940
985
70
±
20
460
±
100 860
±
20 Not needed Not needed Not needed
SL-V52H
52
1030
1020
1065
70
±
20
500
±
100 940
±
20 Not needed Not needed Not needed
SL-V56H
56
1110
1100
1145
70
±
20
540
±
100 1020
±
20 Not needed Not needed Not needed
SL-V60H
60
1190
1180
1225
70
±
20
410
±
100 750
±
100 1100
±
20 Not needed Not needed
SL-V64H
64
1270
1260
1305
70
±
20
440
±
100 810
±
100 1180
±
20 Not needed Not needed
SL-V72H
72
1430
1420
1465
70
±
20
490
±
100 910
±
100 1340
±
20 Not needed Not needed
SL-V80H
80
1590
1580
1625
70
±
20
540
±
100 1020
±
100 1500
±
20 Not needed Not needed
SL-V88H
88
1750
1740
1785
70
±
20
460
±
100 860
±
100 1260
±
100 1660
±
20 Not needed
SL-V96H
96
1910
1900
1945
70
±
20
500
±
100 940
±
100 1380
±
100 1820
±
20 Not needed
SL-V104H
104
2070
2060
2105
70
±
20
540
±
100 1020
±
100 1500
±
100 1980
±
20 Not needed
SL-V112H
112
2230
2220
2265
70
±
20
480
±
100 890
±
100 1310
±
100 1720
±
100 2140
±
20
SL-V120H
120
2390
2380
2425
70
±
20
510
±
100 960
±
100 1400
±
100 1850
±
100 2300
±
20