3-8

System Configuration for the Muting Function

3-31

In

st

allatio

n

to a Mac

h

ine

3

SL-V-M-NO3-E

Wiring the muting inputs

Output of the switch or sensor used as the muting device must be the same as the cable used.

Example: PNP output if PNP cable is used, or NPN output if NPN cable is used.

Also, the muting device must be able to handle a 3 mA current load.

Time chart

Brown

+24 V

Light blue

Light blue/black

(Muting input 2)

(Muting input 1)

Receiver

Switch A1

Switch A2

0 V

Light blue

Light blue
/black

Blue

Receiver

(Muting input 2)

(Muting input 1)

Switch A1

Switch A2

When using the PNP output cable

When using the NPN output cable

NOTE

Sensor A2

ON

OFF

Muted condition

Not muted condition

ON

OFF

Sensor A1

SL-V

No

interruption

Interruption

OSSD

ON

OFF

Light ON

Light OFF

Muting lamp

Within 0.04 to 3 s

Within approx. 5 min.

20 ms max.

20 ms max.