Caution, Examples of wiring, Manual reset mode – KEYENCE SL-V Series User Manual

Page 114

background image

4-4

Examples of Wiring

4-6

Wirin

g

4

SL-V-M-NO4-E

Manual reset mode

When using a simple function type cable (NPN output type cable)

The shielding wire of the NPN output type cable is connected to +24 V line in the SL-V.
Do not connect the shielding wire to 0 V line.

If there are some open wiring (completely disconnected), Insulation on those wire are
needed individually.

Automatic reset mode
When using OSSD only

K3

M

IN

OUT

PLC

K1

K2

S1

S2

K2

K1

Cable insulation: Black

Cable insulation: Grey

Transmitter

Receiv

er

(Inter

loc

k-reset-ready output) Green

(+24 V)

Bro

wn

(+24 V)

Bro

wn

(OSSD2) White

(OSSD1) Blac

k

(Reset input)

Y

ello

w

(EDM input) Red

(W

ait input)

Violet

(A

UX output) Red

(0 V)

Blue

(0 V)

Blue

Shield

Shield

K2

K1

(Inter

loc

k mode selection input) Pink

Orange/black

(Communication cable 2)

Orange

(Communication cable 1)

K1, K2 : External device (Safety relay, magnet contactor,

etc.)

K3

: Solid state contactor

*1

S1

: The switch for wait input (N.O.)

*1

The violet wire needs to be capped it is not used.
(Open circuit : completely disconnected)

S2

: The switch for reset input (N.O.)

M

: 3-phase motor

PLC

: For the monitoring use

*1

*1

These are NON SAFETY-RELATED system.

Caution

K1, K2 : External device (Safety relay unit, etc.)

Cable insulation: Black

Cable insulation: Grey

Transmitter

Receiv

er

(Inter

loc

k-reset-ready output) Green

(+24 V)

Bro

wn

(+24 V)

Bro

wn

(OSSD2) White

(OSSD1) Blac

k

(Reset input)

Y

ello

w

(EDM input) Red

(W

ait input)

Violet

(A

UX output) Red

(0 V)

Blue

(0 V)

Blue

Shield

Shield

K2

K1

(Inter

loc

k mode selection input) Pink

Orange/black

(Communication cable 2)

Orange

(Communication cable 1)