Caution, Examples of wiring, Manual reset mode – KEYENCE SL-V Series User Manual
Page 114
4-4
Examples of Wiring
4-6
Wirin
4
SL-V-M-NO4-E
Manual reset mode
When using a simple function type cable (NPN output type cable)
•
The shielding wire of the NPN output type cable is connected to +24 V line in the SL-V.
Do not connect the shielding wire to 0 V line.
•
If there are some open wiring (completely disconnected), Insulation on those wire are
needed individually.
Automatic reset mode
When using OSSD only
K3
M
IN
OUT
PLC
K1
K2
S1
S2
K2
K1
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiv
er
(Inter
loc
k-reset-ready output) Green
(+24 V)
Bro
wn
(+24 V)
Bro
wn
(OSSD2) White
(OSSD1) Blac
k
(Reset input)
Y
ello
w
(EDM input) Red
(W
ait input)
Violet
(A
UX output) Red
(0 V)
Blue
(0 V)
Blue
Shield
Shield
K2
K1
(Inter
loc
k mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
K1, K2 : External device (Safety relay, magnet contactor,
etc.)
K3
: Solid state contactor
*1
S1
: The switch for wait input (N.O.)
*1
The violet wire needs to be capped it is not used.
(Open circuit : completely disconnected)
S2
: The switch for reset input (N.O.)
M
: 3-phase motor
PLC
: For the monitoring use
*1
*1
These are NON SAFETY-RELATED system.
Caution
K1, K2 : External device (Safety relay unit, etc.)
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiv
er
(Inter
loc
k-reset-ready output) Green
(+24 V)
Bro
wn
(+24 V)
Bro
wn
(OSSD2) White
(OSSD1) Blac
k
(Reset input)
Y
ello
w
(EDM input) Red
(W
ait input)
Violet
(A
UX output) Red
(0 V)
Blue
(0 V)
Blue
Shield
Shield
K2
K1
(Inter
loc
k mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)