This user’s manual mentions that the SL-V units can be connected in series as “main unit” and “sub unit
1”, or “sub unit 2” as follows.

1

Remove the connector cover on the main unit.
Do not remove the cover unless connecting

the unit in series.

2

Connect the series connection cable for
transmitter (cable insulation is grey) to the
portion of connector. (Connector cover has
already been removed in step 1.)
Recommended tightening torque : 0.3 N·m

Minimum cable bending radius

: 5 mm

3

The series connection cable must be also
connected to the sub unit 1.

4

The sub unit 1 can be connected to sub unit 2 in the same manner, if necessary.

Do not remove the grey gasket installed on the connector. Without this gasket the requirement
of IP65 can not be fulfilled.

Series connection cable

Receiv

er

Receiv

er

T

ransmitter

T

ransmitter

Unit connection cable
(30 m max.)

Series connection cable
(10 m max.)

Series connection cable
(10 m max.)

Sub unit 1

Main unit

Sub unit 2

Receiv

er

T

ransmitter

M2.6 screws

M2.6 screws

For transmitters other than SL-VF/
VH/VL

For SL-VFM/VHM/VLM
transmitters

Series connection cable
Transmitter:
cable insulation is grey
Receiver:
cable insulation is black

M2.6
screws

M2.6
screws

Series connection cable
Transmitter:
cable insulation is grey
Receiver:
cable insulation is black

For transmitters other than SL-VF/
VH/VL

For SL-VFM/VHM/VLM
transmitters

Series connection cable

Main unit

Sub unit 1

Series connection cable

Main unit

Sub unit 1

Transmitters other
than SL-VF/VH/VL

Receivers other
than SL-VF/VH/VL

Receivers of
SL-VFM/
VHM/VLM

Transmitters
of SL-VFM/
VHM/VLM

Caution