2-8

State Information Output

2-22

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

Example of a muting lamp error

• When using a PNP output type cable to connect to a PNP input device
• When using an NPN output type cable to connect to an NPN input device

• When using a PNP output type cable to connect to an NPN input device
• When using an NPN output type cable to connect to a PNP input device

AUX

2 pulses (muting function active)

4 pulses (muting lamp error)

Muted condition

40 ms min.

120 ms

20 ms*

20 ms*

20 ms*

20 ms*

ON

OFF

State information

output 1

ON

OFF

State information

output 2

ON

OFF

ON

OFF

OSSD

* This is 100 ms when the

"Pulse speed" on the
SL-VH1S is set to "Slow".