Temporary Suspension of Safety Function

2-44

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

Changing of the condition for initiation of muting (Sequence of muting inputs)

(1) Follow the procedure under "Entering the password".

"Entering the password" (page 2-39)

(2) This setting depends on the state of the override input (red/black wire on the receiver).

ON: The condition for initiation of muting (sequence of muting inputs) is deactivated, which means
that no defined sequence of muting inputs is active. (the interlock indicator on the receiver blinks.)

OFF: The condition for initiation of muting (sequence of muting inputs) is activated, which means the
default sequence is active. (the interlock indicator on the receiver does not light.)

(3) Turn ON the muting input 1.

(4) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action four

times. The bar LED 3 on the receiver light in green.

(5) Turn OFF the muting input 1.

(6) Turn ON the muting input 2.
(7) Turn ON the muting input 1, and then turn OFF the muting input 1. You must repeat this action four

times. The bar LED 3 on the receiver lights in red.

(8) Turn OFF the muting input 2.
(9) If these procedures are performed correctly, the bar LED 3 on the receiver light in green. Afterwards,

the center indicator on the receiver lights in red and then lights in green again approximately one

second later. This indicates that the settings are completed.

(10) Turn OFF the power to the SL-V, and then the interlock mode selection input (pink wire from the

transmitter) must be wired.

"Interlock Function" (page 2-7)

(11) The condition for initiation of muting (time period between muting input 1 and 2) is changed when

the power to the SL-V is turned ON. The SL-V keeps this condition even if the power to the SL-V is

turned OFF.

When another condition for muting, regardless of initiation or termination, is also changed in addition to the
change of the above-mentioned condition, you can continue the procedure for another condition following
the step (9).
On the other hand, when the change of the above-mentioned condition follows the change of another con-
dition for muting, regardless of initiation or termination, you can waive the step (1).

Ex.: Time chart when the sequence of muting inputs (default) is deactivated

Reference

Override input

From here on, the override
input can be either on or off

ON

OFF

Muting input 1

ON

OFF

Muting input 2

ON

OFF

ON

OFF

SL-V

P

erf
or

m "Enter

ing the pass

w

ord"

B

2 s or more

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A: 20 ms or more, B: 40 ms or more

(2)

(3)

(4)

(5)

(7)

(10)

(1)

(6)

(8)