(1) Additional inspection items

The actual distance between the hazardous zone or hazards and the SL-V still keeps greater than the
calculated safety distance.

When the reduced resolution function is applied, the safety distance is accurately calculated based
on the enlarged detection capability, and the SL-V is installed at a distance greater than or equal to
the minimum safety distance away from the hazardous zone or hazard.

When the fixed blanking function is applied, a hazardous clearance that is not protected by the SL-V
may be generated between the obstacle and the SL-V. When such a hazardous clearance is gener-
ated, an additional protective device such as a safeguard is installed.

The stop time of the machine connected to the SL-V has not increased.

There are no loose screws in the mounting bracket.

The unit connection cable or the series connection cable is fastened tightly to the SL-V with no loose

screws.

The OSSD is connected correctly to the machine.

There is no damage to the SL-V that may influence IP65 structure.

The surface of the SL-V is not polluted or damaged.

Beam axes must be aligned. If it is out of alignment, beam axes are aligned.

There is no change of installation that would influence the result of your original risk assessment.