Changing configuration of the muting function, Changing configuration of the muting function -33, Danger – KEYENCE SL-V Series User Manual

Page 57: Procedure for configuration through the sl-vh1s

background image

2-11

Temporary Suspension of Safety Function

2-33

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

The conditions related to muting can be changed through the special procedure on the SL-V or through

the SL-VH1S.
(X: available -: not available)

If you choose these options according to your machine application, password setting and/or password

input is required as a special procedure.
The password can be set on the SL-V main unit or through the configuration software SL-VH1S.

The users who intend to use these options mentioned above from 1 to 3, 5 and 6 have to
perform the risk assessment based on their machine application.

• Muted condition is terminated approx. 5 minutes later when the time between muting inputs exceeds 3

seconds, even if "Not specified" is selected for both maximum muting period of time and time between

muting inputs.

• Password must be secured because the password is necessary to change the condition for initiation

and/or termination of muting or change these conditions back to the default.

The override conditions cannot be changed.

See "Override function" (page 2-45)

Procedure for configuration through the SL-VH1S

Refer to "SL-VH1S User’s Manual".

Changing configuration of the muting function

Item

option

availability

SL-V

SL-VH1S

Changing of the
conditions for initiation
of muting

1. Time period specification of muting inputs
Time period specification of 0.04s to 3s between
muting input 1 and muting input 2 can be changed.
The lower limit of 0.04s cannot be changed.

1 second

-

X

3 seconds (default)

X

X

10 second

-

X

30 second

-

X

Not specified

X

X

2. Sequence specification of muting inputs
Sequence specification of muting inputs can be
changed. (Default sequence: muting input 1 is first,
muting input 2 is second.)

1 -> 2 fixed (default)

X

X

Not specified

X

X

Conditions for
termination of muting

3. Maximum muting period
Maximum muting period of approx. 5 minutes can be
changed.

1 minute

-

X

5 minutes (default)

X

X

10 minutes

-

X

20 minutes

-

X

Not specified

X

X

4. Muting lamp error
Sets whether the SL-V goes to the lockout condition when there is a muting
lamp error.

Only warning (default)

X

X

Lockout

X

X

5. Muting area configuration

-

-

X

6. Muting bank function

Not apply (default)

X

X

Apply

-

X

Danger

NOTE

Reference

Cable

Self-diagnosis

Series Connection

Interlock

AUX

EDM

Wait

State Information

Alert

Clear/Blocked

Suspension

Fixed

Reduced

Monitoring