Front protection cover and dimmer filter, Sl-v configurator (sl-vh1s), Front protection cover and dimmer filter -8 – KEYENCE SL-V Series User Manual
Page 20: Sl-v configurator (sl-vh1s) -8
1-2
Options
1-8
Befo
1
SL-V-M-NO1-E
• To mount the protection bar to the SL-V, standard mounting bracket A (OP-42347), B (OP-42348), C
(OP-42349), or J (OP-83180) is required.
• The bar and the standard mounting bracket are fixed with the hexagon socket bolts, so the angle of the
mounting bracket or the bar cannot be adjusted. However, the angle of the SL-V and the mounting
bracket can be adjusted for beam axis adjustment.
• The protection bar can be mounted to the back or side of the SL-V. Select an appropriate intermediate
support for the protection bar based on the mounting method.
• Install the unit at the angle shown in the following figure so that the protection bar or the intermediate
support bracket does not block the beam axes of the SL-V.
Back mounting
Side mounting
KEYENCE can provide the front protection cover to protect the surface of the SL-V and also provide the
dimmer filter to shorten the operating distance.
Since these are optional, please contact your nearest KEYENCE office for further information.
When the SL-V Configurator is used, the following setting changes and functions are available.
NOTE
15˚
20˚
Front protection cover and dimmer filter
SL-V Configurator (SL-VH1S)
Items
Description
Refer to page
Muting function
You can select the beam axes to be muted. The muting conditions can also be changed.
Muting bank function
You can change the setting whether or not to use the Muting bank function.
When the muting bank function is used, the override function is disabled. Set
the interlock function with the SL-V Configurator because setting of the
interlock function with wiring is disabled.
Override function
You can change the override condition.
Interlock function
The Interlock function enables OSSD to hold the OFF-state if no interruptions
are present in the detection zone upon startup (when the power turns on or the
lockout error condition is terminated by the reset input) or upon restart (when
the SL-V is interrupted and the OSSD becomes the OFF-state). This state is
called "interlock ". To recover from the interlock condition, the reset input must
be switched ON to OFF while no interruptions are present in the detection
zone. Automatic or manual can be selected individually for start and restart.
Automatic start mode : The OSSD automatically enters the ON-state when
no interruptions are present in the detection zone.
Manual start mode
: Enters interlock condition upon startup.
Automatic reset mode : The OSSD automatically returns to the ON-state when
no interruptions are present in the detection zone.
Manual reset mode
: Enters interlock condition upon restart.
Fixed blanking function
This function is enabled only for the specified beam axes. The OSSD can hold
the ON-state even when an interruption is present in the area. A desired area
can be set as an effective zone of this function on a pair of transmitter and the
receiver as well as on the all beam axes including the SL-V connected in
series. The area where this function is enabled can be set as desired not only
between a transmitter-receiver pair, but also on all the beam axes including the
SL-V connected in series.