beautypg.com

Entering the password – KEYENCE SL-V Series User Manual

Page 63

background image

2-11

Temporary Suspension of Safety Function

2-39

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

Entering the password

The password is a four digit number.

Setting procedure
(1) Turn OFF the power to the SL-V.
(2) Disconnect the interlock mode selection input (pink wire on the transmitter) turn OFF the muting

input 1 (light blue wire on the receiver) and muting input 2 (light blue/black wire on the receiver), and
then turn ON the power for the SL-V. The SL-V enters the I/O monitor state.

"I/O Monitoring Function" (page 2-50)

(3) Turn ON the muting input 1.
(4) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action nine times.
(5) Turn OFF the muting input 1.

(6) Turn ON the muting input 2.
(7) Turn ON the muting input 1, and then turn OFF the muting input 1. You must repeat this action three times.
(8) Turn OFF the muting input 2. If these procedures are performed correctly, the center indicator on

receiver lights in green.

Afterwards, you can input the password digit-by-digit in the following order: 4th, 3rd, 2nd and 1st. You

can confirm which the digit is selected through the blinking status of function indicators on the receiver.

"Function Indicators" (page 6-5)

(9) Turn ON the muting input 1.
(10) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action with

the same number of times as the number of 4th digit of password. While you repeat this action, the

bar LEDs on transmitter and receiver light in green corresponding to the number of that action as
shown below.
If you repeat this action 10 times, the number returns to "0".

"Bar LED Indicator" (page 6-2)

Ex.: 0

1

2

3

1st

2nd

3rd

4th

Digits

4th

3rd

2nd

1st

Function indicator

on the receiver

MUTE1

MUTE2

OSSD

INTER

LOCK

MUTE1

MUTE2

OSSD

INTER

LOCK

MUTE1

MUTE2

OSSD

INTER

LOCK

MUTE1

MUTE2

OSSD

INTER

LOCK

Number

0

1

2

3

4

Bar LED

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

Cable

Self-diagnosis

Series Connection

Interlock

AUX

EDM

Wait

State Information

Alert

Clear/Blocked

Suspension

Fixed

Reduced

Monitoring