Troubleshooting
If the SL-V is not operating as desired, refer to the display indicators as shown in the figure below. If the
center indicators are blinking red or the interlock indicator is blinking yellow then the SL-V is in a lockout
condition.
If the SL-V has detected any kind of irregularity, the OSSD (output control) will lock itself in the OFF state.
When this occurs, bar LEDs 1 through 5 will indicate the source of the problem and the center display
light will blink red.
Additionally, output 2 will indicate the source of the problem via the number of pulses it scintillates.
To terminate the lockout condition, remedy the problem indicated and recycle power.
See "State Information Output" (page 2-18)
LEVEL
WAIT
FUNCTION
OSSD
INTER
LOCK
ø25 (0.98")
SL-V08H
1
2
3
4
5
Transmitter
LED bar indicator
Function indicator
LEVEL
MUTE1
MUTE2
OSSD
INTER
LOCK
ø25 (0.98")
SL-V08H
1
2
3
4
5
Receiver
LED bar indicator
Function indicator
Indicator color
Red or green
Red or green
Red or green
Red or green
Red or green
Orange
Orange
Red or green
Yellow
If the device is in the lockout condition