beautypg.com

Time chart, Time chart when using wait input – KEYENCE SL-V Series User Manual

Page 36

background image

2-4

Interlock Function

2-12

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

Time chart

Time chart in case of interruption in the detection zone.

(1) When using a PNP output type cable to connect to a PNP input device, or when using an NPN out-

put type cable to connect to an NPN input device

(2) When using a PNP output type cable to connect to an NPN input device, or when using an NPN out-

put type cable to connect to a PNP input device

T1 : Response time (OSSD) (

page 7-7)

The interlock can be terminated due to the reset input if the SL-V detects no interruption in the detection

zone. This operation does not relate to the condition of the Interlock-reset-ready output state because this

output is a non-safety output.

Time chart when using wait input

See "Wait Input Function" (page 2-16)

(1) When using a PNP output type cable to connect to a PNP input device, or when using an NPN out-

put type cable to connect to an NPN input device

(2) When using a PNP output type cable to connect to an NPN input device, or when using an NPN out-

put type cable to connect to a PNP input device

The interlock can be terminated due to the reset input if the SL-V detects no interruption in the detection zone. This opera-

tion does not relate to the condition of the Interlock-reset-ready output state because this output is a non-safety output.

No

interruption

Interruption

ON

SL-V

(1)

(2)

Reset input

Interlock-reset-ready
output

Interlock

T1

150 ms max.

100 ms max.

100 ms min.

OFF

ON

OFF

ON

OFF

ON

OFF

OSSD

NOTE

SL-V

No

interruption

Interruption

ON

(1)

Wait input

(2)

Reset input

Interlock-reset-ready
output

Interlock

150 ms max.

100 ms max.

200 ms max.

100 ms min.

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OSSD

NOTE