Time chart, Time chart when using wait input – KEYENCE SL-V Series User Manual
Page 36
2-4
Interlock Function
2-12
2
SL-V-M-NO2-E
Time chart
Time chart in case of interruption in the detection zone.
(1) When using a PNP output type cable to connect to a PNP input device, or when using an NPN out-
put type cable to connect to an NPN input device
(2) When using a PNP output type cable to connect to an NPN input device, or when using an NPN out-
put type cable to connect to a PNP input device
T1 : Response time (OSSD) (
The interlock can be terminated due to the reset input if the SL-V detects no interruption in the detection
zone. This operation does not relate to the condition of the Interlock-reset-ready output state because this
output is a non-safety output.
Time chart when using wait input
See "Wait Input Function" (page 2-16)
(1) When using a PNP output type cable to connect to a PNP input device, or when using an NPN out-
put type cable to connect to an NPN input device
(2) When using a PNP output type cable to connect to an NPN input device, or when using an NPN out-
put type cable to connect to a PNP input device
The interlock can be terminated due to the reset input if the SL-V detects no interruption in the detection zone. This opera-
tion does not relate to the condition of the Interlock-reset-ready output state because this output is a non-safety output.
No
interruption
Interruption
ON
SL-V
(1)
(2)
Reset input
Interlock-reset-ready
output
Interlock
T1
150 ms max.
100 ms max.
100 ms min.
OFF
ON
OFF
ON
OFF
ON
OFF
OSSD
NOTE
SL-V
No
interruption
Interruption
ON
(1)
Wait input
(2)
Reset input
Interlock-reset-ready
output
Interlock
150 ms max.
100 ms max.
200 ms max.
100 ms min.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OSSD
NOTE