Arc Machines 307 User Manual
Page 56

Arc Machines, Inc. Model 307 Orbital Tube Welder Training
Document No. 740096
Chapter 5. Page 7.
Rev. A
Level Time - Level Time is the time the electrode will
travel during a particular level. If Level Position is pro-
grammed, Level Time will be automatically adjusted
accordingly. For auto-generated weld schedules, Travel
Start Delay time is added to Level 1 time while overlap (tie-
in) is added to Level 4 time.