Arc Machines, Inc. Model 307 Orbital Tube Welder Training
Document No. 740096
Chapter 12. Page 2.
Rev.A
To make a Test Run of a weld schedule, open the
schedule and from the Weld Schedule - Main screen,
touch the grey Single Entry button. Set downslope to
0.0 and touch OK.
From the Weld Schedule - Main Screen, touch the grey Weld
button to show the Weld Schedule - Weld screen with the
green Test button. To make the Test Run, touch the red
Start button. Verify that the electrode travels 360° plus the
desired overlap or tie-in. Adjust time and or level position as
necessary.
At the end of the
TEST
RUN
, re-enter the
DOWNSLOPE
TIME
.