Manual calibration of weld heads – Arc Machines 307 User Manual
Page 137

Arc Machines, Inc. Model 307 Orbital Tube Welder Training
Document No. 740096 Chapter 13. Page 4
Rev. A
Manual Calibration of Weld Heads
For Manual Calibration of Weld Heads use the RPM and Times shown in
Table 1 to write schedules for calibration of each individual weld head.
Important: Calibration (automatic or manual) must be performed each time
a different weld head is connected to the Model 307 Power Supply.
Table 1: RPM and Times for Manual Calibration of Weld Heads
Model 9-250
6 RPM
10 Seconds
Model 9-500C
6 RPM
10 Seconds
Model 9AF-750
4 RPM
15 Seconds
Model 9-1500
4 RPM
15 Seconds
Model 9-2500
2 RPM
30 Seconds
Model 9-3500
2 RPM
30 Seconds
Model 9-4500
2 RPM
30 Seconds
Model 9-7500
10 RPM (10 = 1)
60 Seconds
Model 8-2000
4 RPM
15 Seconds
Model 8-4000
4 RPM
15 Seconds
Model 8-6625
1 RPM
60 Seconds
Model 4-500
6 RPM
10 Seconds