Arc Machines 307 User Manual
Page 38
Arc Machines, Inc. Model 307 Orbital Tube Welder Training
Document No. 740096
Chapter 4. Page 4.
Rev. A
supply. From the Home screen touch "Shutdown". Wait for "It’s
now safe to turn off your computer" to appear on the screen
before turning the circuit breaker OFF.
MODEL 307 POWER SUPPLY ADAPTER CABLE CONNECTIONS
To connect the ELECTRODE and GROUND connectors to their respective
terminals on the Model 307, align the keyways, push in and twist
clockwise until fully locked.
GROUND
Weld head or adapter cable connections to the Model 307 Power Supply for Weld Head
Motor Control, Electrode, Ground and Arc Gas.
ELECTRODE
WELD HEAD
MOTOR CONTROL
ARC GAS OUTPUT
GROUND
ELECTRODE AND GROUND CABLES
WELD HEAD CONTROL CABLE
Plug cables in with keyways up and turn
clockwise until locked.
Insert motor connector with keyway aligned
and tighten locking rings.
WELD HEAD CONTROL CABLE