Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual
Page 98

3–22
Status Word/Bit Descriptions
Publication 1771-6.5.126 – March 1998
Notes: For [ ] engineering units, see page 2.
Word
Bit
Description
SYS18
Status of Last Successful Decode
The module latches one of the bits in SYS17 and SYS18 (while unlatching all others) when it successfully decodes the
referenced command block and places the new data into operational memory. The module does not latch any bit asso-
ciated with an unrecognizable command block. Set no more than one bit at a time in SYS17 and SYS18.
This bit
latched ON:
when last successful decode was:
B00-07
RFU
B08
DYC
B09
RLC
B10
RFU
B11
PTC
B12-B15
RFU
SYS19
Programming-error Alarms
The module latches bits when it attempts to decode a newly received copy of the subject command block and is forced
to discard the data due to the presence of a programming error in the newly received block. The module does not latch
any bit associated with an unrecognizable command block. The module unlatches each bit when it successfully de-
codes the referenced command block and places the new data into operational memory.
This bit
latched
ON:
when the module detected a programming error in:
B00
MCC The module ceases all action execution and sets its outputs to zero when forced to set this bit. The module
does not respond to any action execution commands as long as this bit remains SET.
B01
JGC
B02-06
RFU
B07
INC
B08
IPC
B09
PKC
B10
HDC
B11
HPC
B12
PRC
B13
PLC
B14
PPC
B15
PSC
SYS20
Programming-error Alarms
The module latches bits when it attempts to decode a newly received copy of the subject command block and is forced
to discard the data due to the presence of a programming error in the newly received block. The module does not latch
any bit associated with an unrecognizable command block. The module unlatches each bit when it successfully de-
codes the referenced command block and places the new data into operational memory.
This bit
latched ON:
when the module detected a programming error in:
B00-07
RFU
B08
DYC The module ceases all action execution and sets its outputs to zero when forced to set this bit. The module
does not respond to any action execution commands as long as this bit remains SET.
B09
RLC
B10
RFU
B11
PTC
B12-B15
RFU