Command Word/Bit Descriptions

Publication 1771-6.5.126 – March 1998

INC

Output Ramp Rates

The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Injection Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).

Word

Description

INC17

Output #1 Acceleration Ramp Rate during Profile [20]

INC18

Output #2 Acceleration Ramp Rate during Profile [20]

INC19

Output #3 Acceleration Ramp Rate during Profile [20]

INC20

Output #4 Acceleration Ramp Rate during Profile [20]

INC21-24

RFU

INC25

Output #1 Deceleration Ramp Rate during Profile [20]

INC26

Output #2 Deceleration Ramp Rate during Profile [20]

INC27

Output #3 Deceleration Ramp Rate during Profile [20]

INC28

Output #4 Deceleration Ramp Rate during Profile [20]

INC29-32

RFU

End of Profile Set-output Values

When module completes the Injection Profile and IPC02-B08 is SET, it:

sets status bit SYS02-B04

uses ramp rates INC17-20 and INC25-28 when changing outputs

sets its outputs to the following values

Word

Description

INC33

Output #1 Set-output Value at End of Profile [19]

INC34

Output #2 Set-output Value at End of Profile [19]

INC35

Output #3 Set-output Value at End of Profile [19]

INC36

Output #4 Set-output Value at End of Profile [19]

INC37-40

RFU

Pressure Control Limits

Word

Description

INC41

Pressure Minimum Control Limit [01] Minimum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Injection Profile. The module expects this ram (screw) pressure when setting its selected pressure valve to the %-output in INC43.

INC42

Pressure Maximum Control Limit [01] Maximum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Injection Profile. The module expects this ram (screw) pressure when setting its selected pressure valve to the %-output in INC44.

INC43

Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos or Press/Time Injection Profile. The module expects a pressure equal to INC41 when setting the se-
lected pressure valve to this %-output during profile execution. The Press/Pos or Press/Time Injection Profile will be executed as a
reverse-acting algorithm if this entry is greater than INC44.

INC44

Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos or Press/Time Injection Profile. The module expects a pressure equal to INC42 when setting the se-
lected pressure valve to this %-output during profile execution. The Press/Pos or Press/Time Injection Profile will be executed as a