Command Word/Bit Descriptions
Publication 1771-6.5.126 – March 1998
INC
Output Ramp Rates
The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Injection Profile. The module
interprets a ramp rate of zero as a step function ramp (ramp disable).
Word
Description
INC17
Output #1 Acceleration Ramp Rate during Profile [20]
INC18
Output #2 Acceleration Ramp Rate during Profile [20]
INC19
Output #3 Acceleration Ramp Rate during Profile [20]
INC20
Output #4 Acceleration Ramp Rate during Profile [20]
INC21-24
RFU
INC25
Output #1 Deceleration Ramp Rate during Profile [20]
INC26
Output #2 Deceleration Ramp Rate during Profile [20]
INC27
Output #3 Deceleration Ramp Rate during Profile [20]
INC28
Output #4 Deceleration Ramp Rate during Profile [20]
INC29-32
RFU
End of Profile Set-output Values
When module completes the Injection Profile and IPC02-B08 is SET, it:
•
sets status bit SYS02-B04
•
uses ramp rates INC17-20 and INC25-28 when changing outputs
•
sets its outputs to the following values
Word
Description
INC33
Output #1 Set-output Value at End of Profile [19]
INC34
Output #2 Set-output Value at End of Profile [19]
INC35
Output #3 Set-output Value at End of Profile [19]
INC36
Output #4 Set-output Value at End of Profile [19]
INC37-40
RFU
Pressure Control Limits
Word
Description
INC41
Pressure Minimum Control Limit [01] Minimum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Injection Profile. The module expects this ram (screw) pressure when setting its selected pressure valve to the %-output in INC43.
INC42
Pressure Maximum Control Limit [01] Maximum controllable ram (screw) pressure attainable during any Press/Pos or Press/Time
Injection Profile. The module expects this ram (screw) pressure when setting its selected pressure valve to the %-output in INC44.
INC43
Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos or Press/Time Injection Profile. The module expects a pressure equal to INC41 when setting the se-
lected pressure valve to this %-output during profile execution. The Press/Pos or Press/Time Injection Profile will be executed as a
reverse-acting algorithm if this entry is greater than INC44.
INC44
Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos or Press/Time Injection Profile. The module expects a pressure equal to INC42 when setting the se-
lected pressure valve to this %-output during profile execution. The Press/Pos or Press/Time Injection Profile will be executed as a
reverse-acting algorithm if this entry is less than INC43.