Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual
Page 112

4–10
Programming Error Codes
Publication 1771-6.5.126 – March 1998
Error Code
Description
IPC ID = 9
0411
IPC11 is out of range.
if:
then:
MCC13 and MCC14
IPC11 must be within 00000
≤
IPC11
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC11 must be within 00000
≤
IPC11
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC11 must be within 00000
≤
IPC11
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC11 must be within 00000
≤
IPC11
≤
MCC10 – MCC09
are both zero
0413
IPC13 is out of range.
When IPC03-B14 = 1, a non-zero IPC13 must be within INC45
≤
IPC13
≤
INC46
0414
IPC14 is out of range.
If non-zero, IPC14 must be within INC41
≤
IPC14
≤
INC42
0415
IPC15 is out of range.
if:
then:
MCC13 and MCC14
IPC15 must be within 00000
≤
IPC15
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC15 must be within 00000
≤
IPC15
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC15 must be within 00000
≤
IPC15
≤
MCC14 – MCC09
MCC14 is non-zero
MCC13 and MCC14
IPC15 must be within 00000
≤
IPC15
≤
MCC10 – MCC09
are both zero
0417
IPC17 is out of range.
When IPC03-B14 = 1, a non-zero IPC17 must be within INC45
≤
IPC17
≤
INC46
0418
IPC18 is out of range.
If non-zero, IPC18 must be within INC41
≤
IPC18
≤
INC42
0419
IPC19 is out of range.
if:
then:
MCC13 and MCC14
IPC19 must be within 00000
≤
IPC19
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
PC19 must be within 00000
≤
IPC19
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC19 must be within 00000
≤
IPC19
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC19 must be within 00000
≤
IPC19
≤
MCC10 – MCC09
are both zero
0421
IPC21 is out of range.
When IPC03-B14 = 1, a non-zero IPC21 must be within INC45
≤
IPC21
≤
INC46
0422
IPC22 is out of range.
If non-zero, IPC22 must be within INC41
≤
IPC22
≤
INC42
0423
IPC23 is out of range.
if:
then:
MCC13 and MCC14
IPC23 must be within 00000
≤
IPC23
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC23 must be within 00000
≤
IPC23
≤
MCC10 – MCC13
MCC14 is zero .
MCC13 is zero and
IPC23 must be within 00000
≤
IPC23
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC23 must be within 00000
≤
IPC23
≤
MCC10 – MCC09
are both zero
0425
IPC25 is out of range.
When IPC03-B14 = 1, a non-zero IPC25 must be within INC45
≤
IPC25
≤
INC46