Programming Error Codes
Publication 1771-6.5.126 – March 1998
Error Code
Description
MCC ID = 1
0248
MCC48 is out of range. MCC48 must be within:
00000
≤
MCC48
≤
01000 (0 to 10 V dc sensor)
00100
≤
MCC48
≤
00500 (1 to 5 V dc sensor)
00400
≤
MCC48
≤
02000 (4 to 20 mA dc sensor)
0250
MCC50 is out of range. Valid range is 00000
≤
MCC50
≤
00099
0253
MCC53 is out of range. MCC53 must be within:
00000
≤
MCC53
≤
01000 (0 to 10 V dc sensor)
00100
≤
MCC53
≤
00500 (1 to 5 V dc sensor)
00400
≤
MCC53
≤
02000 (4 to 20 mA dc sensor)
0254
MCC54 is out of range. MCC54 must be within:
00000
≤
MCC54
≤
01000 (0 to 10 V dc sensor)
00100
≤
MCC54
≤
00500 (1 to 5 V dc sensor)
00400
≤
MCC54
≤
02000 (4 to 20 mA dc sensor)
0256
MCC56 is out of range. Valid range is 00000
≤
MCC56
≤
00099
0259
MCC59 is out of range. MCC59 must be within:
00000
≤
MCC59
≤
01000 (0 to 10 V dc sensor)
00100
≤
MCC59
≤
00500 (1 to 5 V dc sensor)
00400
≤
MCC59
≤
02000 (4 to 20 mA dc sensor)
0260
MCC60 is out of range. MCC60 must be within
00000
≤
MCC60
≤
01000 (0 to 10 V dc sensor)
00100
≤
MCC60
≤
00500 (1 to 5 V dc sensor)
00400
≤
MCC60
≤
02000 (4 to 20 mA dc sensor)
0262
MCC62 is out of range. Valid range is 00000
≤
MCC62
≤
00099
0263
MCC63 is out of range. Valid range is 00000
≤
MCC63
≤
00099
0311
MCC11 is equal to MCC12. They must not be equal.
0319
MCC19 is equal to MCC20. They must not be equal.
0325
MCC25 is equal to MCC26. They must not be equal.
0333
MCC33 is equal to MCC34. They must not be equal.
0339
MCC39 is equal to MCC40. They must not be equal.
0347
MCC47 is equal to MCC48. They must not be equal.
0353
MCC53 is equal to MCC54. They must not be equal.
0359
MCC59 is equal to MCC60. They must not be equal.
0405-0408
Your entry for MCC05-MCC08 is out of range. Valid range is –1000
≤
entry
≤
+1000.
0409
MCC09 is out of range. Valid range is 00000
≤
MCC09 < MCC10
0410
MCC10 is out of range. Valid range is MCC09 < MCC10
≤
09999
0413
Your non-zero entry for MCC13 is out of range. If MCC14 is non-zero, MCC13 must be
within MCC09
≤
MCC13 < MCC14
If MCC14 is zero, MCC13 must be within MCC09
≤
MCC13 < MCC10
0414
Your non-zero entry for MCC14 is out of range. If MCC13 is non-zero, MCC14 must be
within MCC13 < MCC14
≤
MCC10
If MCC13 is zero, MCC14 must be within MCC09 < MCC14
≤
MCC10
0417
MCC17 is out of range. Valid range is 00000
≤
MCC17 < MCC18
0418
MCC18 is out of range. Valid range is MCC17 < MCC18
≤
09999
0421
MCC21 is out of range.
If non-zero, MCC21 must be within MCC17 < MCC21
≤
MCC18
0423
MCC23 is out of range. Valid range is 00000
≤
MCC23 < MCC24
0424
MCC24 is out of range. Valid range is MCC23 < MCC24
≤
09999
0427
Your non-zero entry for MCC27 is out of range.
If MCC28 is non-zero, MCC27 must be within MCC23
≤
MCC27 < MCC28
If MCC28 is zero, MCC27 must be within MCC23
≤
MCC27 < MCC24