beautypg.com

Rls ú inject erc values status block, Rls – inject erc values status block – Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual

Page 30

background image

1–20

Abbreviated Command and Status Blocks

Publication 1771-6.5.126 – March 1998

Starting Data Points from Injection Profile (continued)

PTS20

N132:71

Inject segment 6 start data point

PTS21

N132:72

Inject segment 7 start data point

PTS22

N132:73

Inject segment 8 start data point

PTS23

N132:74

Inject segment 9 start data point

PTS24

N132:75

Inject segment 10 start data point

PTS25

N132:76

Inject segment 11 start data point

Starting Data Points from Pack/Hold Profiles

PTS26

N132:77

Pack segment 1 start data point

PTS27

N132:78

Pack segment 2 start data point

PTS28

N132:79

Pack segment 3 start data point

PTS29

N132:80

Pack segment 4 start data point

PTS30

N132:81

Pack segment 5 start data point

PTS31

N132:82

Hold segment 1 start data point

PTS32

N132:83

Hold segment 2 start data point

PTS33

N132:84

Hold segment 3 start data point

PTS34

N132:85

Hold segment 4 start data point

PTS35

N132:86

Hold segment 5 start data point

PTS36

N132:87

Pre-decompress start data point

Starting Data Points from Plastication Profile

PTS37

N132:88

Plastication segment 1 start data point

PTS38

N132:89

Plastication segment 2 start data point

PTS39

N132:90

Plastication segment 3 start data point

PTS40

N132:91

Plastication segment 4 start data point

PTS41

N132:92

Plastication segment 5 start data point

PTS42

N132:93

Plastication segment 6 start data point

PTS43

N132:94

Plastication segment 7 start data point

PTS44

N132:95

Plastication segment 8 start data point

PTS45

N132:96

Plastication segment 9 start data point

PTS46

N132:97

Plastication segment 10 start data point

PTS47

N132:98

Plastication segment 11 start data point

PTS48

N132:99

Post-decompress start data point

PTS49 - 64

N132:100-115

RFU

Word

Pro-Set Address

Description

Bit-mapped Status Words

RLS01

B34:0

Block ID 00001000 (lower byte)

RLS01

B34:0

Jog status (upper byte)

RLS02

B34:1

Status of profile execution

RLS03

B34:2

Miscellaneous status

RLS04

B34:3

Status of watchdog timers

ERC Actuals from Injection Profile

RLS05-08

N44:541-544

RFU

RLS09

N44:545

Injection segment 1

RLS10

N44:546

Injection segment 2

RLS11

N44:547

Injection segment 3

RLS12

N44:548

Injection segment 4

RLS13

N44:549

Injection segment 5

RLS – Inject ERC Values
Status Block