Ips ú injection profile status block, Ips – injection profile status block – Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual
Page 26
1–16
Abbreviated Command and Status Blocks
Publication 1771-6.5.126 – March 1998
Actuals from Hold Profile
HPS26
N44:674
Segment 1 cavity pressure
HPS27
N44:675
Segment 1 ram (screw) pressure
HPS28
N44:676
End of Segment 1 position
HPS29
N44:677
Segment 2 cavity pressure
HPS30
N44:678
Segment 2 ram (screw) pressure
HPS31
N44:679
End of Segment 2 position
HPS32
N44:680
Segment 3 cavity pressure
HPS33
N44:681
Segment 3 ram (screw) pressure
HPS34
N44:682
End of Segment 3 position
HPS35
N44:6834
Segment 4 cavity pressure
HPS36
N44:684
Segment 4 ram (screw) pressure
HPS37
N44:685
End of Segment 4 position
HPS38
N44:686
Segment 5 cavity pressure
HPS39
N44:687
Segment 5 ram (screw) pressure
HPS40
N44:688
End of Segment 5 position
HPS41-50
N44:689-698
RFU
Maximum Pressures During Pack
HPS51
N44:699
Ram (screw)
HPS52
N44:700
Cavity
Maximum Pressures During Hold
HPS53
N44:701
Ram (screw)
HPS54
N44:702
Cavity
Maximum Pressure During Pre-decompression
HPS55
N44:703
Ram (screw)
HPS56
N44:704
RFU
Profile Execution Times
HPS57
N44:705
During pack
HPS58
N44:706
During hold
HPS59
N44:707
During pre-decompression
HPS60
N44:708
RFU
Actuals from Pre-decompression Movement
HPS61
N44:709
Velocity
HPS62
N44:710
Pressure
End of Hold Ram (Screw) Position
HPS63
N44:711
Position at End of-hold
HPS64
N44:712
RFU
Word
Pro-Set Address
Description
Bit-mapped Status Words
IPS01
B34:0
Block ID 00000011 (lower byte)
IPS01
B34:0
Jog status (upper byte)
IPS02
B34:1
Status of profile execution
IPS03
B34:2
Miscellaneous status
IPS04
B34:3
Status of watchdog timers
IPS05
B38:40
Status of pressure limit alarms
IPS06
B38:41
Status of injection transitions
IPS07
B38:42
CV high limit alarms
IPS08
B38:43
CV low limit alarms
IPS – Injection Profile