4–24
Programming Error Codes
Publication 1771-6.5.126 – March 1998
Error Code
Description
PPC ID = 15
0423
PPC23 is out of range.
if:
then:
MCC13 and MCC14
PPC23 must be within 00000
≤
PPC23
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
PPC23 must be within 00000
≤
PPC23
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
PPC23 must be within 00000
≤
PPC23
≤
MCC14 – MCC09
MCC14 is non-zero .
MCC13 and MCC14
PPC23 must be within 00000
≤
PPC23
≤
MCC10 – MCC09
are both zero
0426
PPC26 is out of range.
If non-zero, PPC26 must be within PLC41
≤
PPC26
≤
PLC42
0427
PPC27 is out of range.
if:
then:
MCC13 and MCC14
PPC27 must be within 00000
≤
PPC27
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
PPC27 must be within 00000
≤
PPC27
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
PPC27 must be within 00000
≤
PPC27
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
PPC27 must be within 00000
≤
PPC27
≤
MCC10 – MCC09
are both zero
0430
PPC30 is out of range.
If non-zero, PPC30 must be within PLC41
≤
PPC30
≤
PLC42
0431
PPC31 is out of range.
if:
then:
MCC13 and MCC14
PPC31 must be within 00000
≤
PPC31
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
PPC31 must be within 00000
≤
PPC31
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
PPC31 must be within 00000
≤
PPC31
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
PPC31 must be within 00000
≤
PPC31
≤
MCC10 – MCC09
are both zero
0434
PPC34 is out of range.
If non-zero, PPC34 must be within PLC41
≤
PPC34
≤
PLC42
0435
PPC35 is out of range.
if:
then:
MCC13 and MCC14
PPC35 must be within 00000
≤
PPC35
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
PPC35 must be within 00000
≤
PPC35
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
PPC35 must be within 00000
≤
PPC35
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
PPC35 must be within 00000
≤
PPC35
≤
MCC10 – MCC09
are both zero
0438
PPC38 is out of range.
If non-zero, PPC38 must be within PLC41
≤
PPC38
≤
PLC42