beautypg.com

Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual

Page 95

background image

3–19

Status Word/Bit Descriptions

Publication 1771-6.5.126 – March 1998

SYS

Word

Bit

Description

SYS13

B07

= 0 Normal
= 1 Hold Profile Command Error
The module latches this bit when both of the following are true:

S DYC02-B06 is SET

S SYS15-B11 is RESET
The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B06.

B08

= 0 Normal
= 1 Pre-decompression Movement Command Error
The module latches this bit at completion of the Hold Profile if all of the following are true:

S HPC03-B08 is RESET

S HPC03-B09 is SET

S SYS15-B12 is RESET
The module also latches this bit if all of the following are true:

S DYC02-B07 is SET

S HPC03-B09 is SET

S SYS15-B12 is RESET
The module also latches this bit if both of the following are true:

S DYC02-B07 is SET

S SYS15-B11 is RESET
The module also latches this bit if both of the following are true:

S DYC02-B07 is SET

S PRC05 added to the actual ram (screw) position equals or exceeds MCC12
Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than DYC02-B07.

B09

= 0 Normal
= 1 Plastication Profile Command Error
The module latches this bit at completion of the Hold Profile if all of the following are true:

S HPC03-B08 is RESET

S SYS15-B12 is RESET

S HPC03-B09 is RESET

S SYS15-B14 is RESET
The module also latches this bit at completion of the Pre-decompression Movement if both of the following are true:

S HPC03-B09 is RESET

S SYS15-B14 is RESET
The module also latches this bit if all of the following are true:

S DYC02-B07 is RESET

S PRC05 equal zero

S HPC03-B09 is RESET

S SYS15-B14 is RESET
The module also latches this bit if all of the following are true:

S DYC02-B07 is RESET

S SYS15-B12 is RESET

S HPC03-B09 is RESET

S SYS15-B14 is RESET
The module also latches this bit if both of the following are true:

S DYC02-B08 is SET

S SYS15-B14 is RESET
The module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than
DYC02-B07 or DYC02-B08.