2–15

Command Word/Bit Descriptions

Publication 1771-6.5.126 – March 1998

HPC

Hold Profile Setpoints

Word

Description

HPC26

Hold Segment 1 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint after starting the Hold Profile for time period specified by HPC28.

HPC27

Hold Segment 1 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint after starting the Hold Profile for time period specified by HPC28.

HPC28

Hold Segment 1 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC26 or HPC27 for this
time period beginning with initiation of the Hold Profile.

HPC29

Hold Segment 2 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint at completion of segment 1 for time period specified by HPC31.

HPC30

Hold Segment 2 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 1 for time period specified by HPC31.

HPC31

Hold Segment 2 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC29 or HPC30 for this
time period beginning at completion of Segment 1.

HPC32

Hold Segment 3 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint at completion of segment 2 for time period specified by HPC34.

HPC33

Hold Segment 3 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 2 for time period specified by HPC34.

HPC34

Hold Segment 3 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC32 or HPC33 for this
time period beginning at completion of Segment 2.

HPC35

Hold Segment 4 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint at completion of segment 3 for time period specified by HPC37.

HPC36

Hold Segment 4 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 3 for time period specified by HPC37.

HPC37

Hold Segment 4 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC35 or HPC36 for this
time period beginning at completion of Segment 3.

HPC38

Hold Segment 5 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure to
this setpoint at completion of segment 4 for time period specified by HPC40.

HPC39

Hold Segment 5 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 4 for time period specified by HPC40.

HPC40

Hold Segment 5 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC38 or HPC39 for this
time period beginning at completion of Segment 4.

Hold Profile Offsets

Word

Description

HPC41

Hold Profile Cavity Pressure Offset [04] If you select Cav Press/Time profile execution, the module applies this entry (after reading
the sign bit) to each cavity pressure profile setpoint.

HPC42

Hold Profile Ram (Screw) Pressure Offset [01] If you select Ram Press/Time profile execution, the module applies this entry (after
reading the sign bit) to each ram (screw) pressure profile setpoint.

HPC43 - 60

RFU

Critical Process Setpoints

Word

Description

HPC61

Cure Timer Preset [22]
At completion of the Hold Profile, the module:

S starts an internal Cure Timer

S sets master status bit SYS03-B03

S reports the accumulated time in SYS58
When the Cure Timer accumulated value in SYS58 equals this entry, the module:

S resets master status bit SYS03-B03

S sets master status bit SYS03-B05

S stops accumulating time in SYS58
If it receives an F-to-T transition of DYC02-B00, -B01, -B02, -B03 or DYC03-B01, the module:

S resets master status bit SYS03-B03

S resets master status bit SYS03-B05

S resets SYS58 to zero

HPC62 - 64

RFU