Abbreviated Command and Status Blocks
Publication 1771-6.5.126 – March 1998
Cavity Pressure Sensor Configuration
MCC57
N40:53
Minimum pressure
MCC58
N40:54
Maximum pressure
MCC59
N40:55
Analog signal @ min pressure
MCC60
N40:56
Analog signal @ max pressure
MCC61
N40:57
High pressure alarm setpoint
MCC62
N40:58
Time delay for pressure alarms
MCC63
N40:59
Switchover time delay, input 3: cavity pressure/RPM
MCC64
N40:60
Number of input samples for loss-of-sensor alarms
Word
Pro-Set Address
Description
Bit-mapped Control Words
PKC01
B38:8
Block ID 00000000 00001010
PKC02
B38:9
Selected valve configurations
PKC03-04
B38:10-11
RFU
Expert Response Compensation Percentage
PKC05
N44:121
ERC % minimum cavity pressure
PKC06
N44:122
ERC % minimum ram pressure
PKC07-08
N44:123-124
RFU
Set-output Values for Unselected Valves (During Profile)
PKC09
N44:125
Output #1
PKC10
N44:126
Output #2
PKC11
N44:127
Output #3
PKC12
N44:128
Output #4
PKC13-16
N44:129-132
RFU
Acceleration Ramp Rates
PKC17
N44:133
Output #1
PKC18
N44:134
Output #2
PKC19
N44:135
Output #3
PKC20
N44:136
Output #4
PKC21-24
N44:137-140
RFU
Deceleration Ramp Rates
PKC25
N44:141
Output #1
PKC26
N44:142
Output #2
PKC27
N44:143
Output #3
PKC28
N44:144
Output #4
PKC29-40
N44:145-156
RFU
Ram (Screw) Pressure Control Limits
PKC41
N44:157
Minimum limit
PKC42
N44:158
Maximum limit
PKC43
N44:159
% output for minimum
PKC44
N44:160
% output for maximum
Cavity Pressure Control Limits
PKC45
N44:161
Minimum limit
PKC46
N44:162
Maximum limit
PKC47
N44:163
% output for minimum
PKC48
N44:164
% output for maximum
PKC – Pack
Configuration Block