Command Word/Bit Descriptions

Publication 1771-6.5.126 – March 1998

Notes: For [ ] engineering units, see page 2.

Word

Bit

Description

HPC04

B04-07

RFU

ERC Enabled/Disabled Selection

B08

= 0 Ram Press/Time Pack Profiles ERC On
= 1 Ram Press/Time Pack Profiles ERC Off

B09

= 0 Cav Press/Time Pack Profiles ERC On
= 1 Cav Press/Time Pack Profiles ERC Off

B10

= 0 Ram Press/Time Hold Profiles ERC On
= 1 Ram Press/Time Hold Profiles ERC Off

B11

= 0 Cav Press/Time Hold Profiles ERC On
= 1 Cav Press/Time Hold Profiles ERC Off

B12-15

RFU

HPC05 - 08

RFU

Pack Profile Setpoints

Word

Description

HPC09

Pack Segment 1 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint after starting the Pack Profile for time period specified by HPC11.

HPC10

Pack Segment 1 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint after starting the Pack Profile for time period specified by HPC11.

HPC11

Pack Segment 1 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC09 or HPC10 for this
time period beginning with initiation of the Pack Profile.

HPC12

Pack Segment 2 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 1 for time period specified by HPC14.

HPC13

Pack Segment 2 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 1 for time period specified by HPC14.

HPC14

Pack Segment 2 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC12 or HPC13 for this
time period beginning at completion of Segment 1.

HPC15

Pack Segment 3 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 2 for time period specified by HPC17.

HPC16

Pack Segment 3 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 2 for time period specified by HPC17.

HPC17

Pack Segment 3 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC15 or HPC16 for this
time period beginning at completion of Segment 2.

HPC18

Pack Segment 4 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 3 for time period specified by HPC20.

HPC19

Pack Segment 4 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 3 for time period specified by HPC20.

HPC20

Pack Segment 4 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC18 or HPC19 for this
time period beginning at completion of Segment 3.

HPC21

Pack Segment 5 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 4 for time period specified by HPC23.

HPC22

Pack Segment 5 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 4 for time period specified by HPC23.

HPC23

Pack Segment 5 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC21 or HPC22 for this
time period beginning at completion of Segment 4.

Pack Profile Offsets

Word

Description

HPC24

Pack Profile Cavity Pressure Offset [04] If you select Cav Press/Time profile execution , the module applies this entry (after reading
the sign bit) to each cavity pressure profile setpoint.

HPC25

Pack Profile Ram (Screw) Pressure Offset [01] If you select Ram Press/Time profile execution, the module applies this entry (after