Command Word/Bit Descriptions
Publication 1771-6.5.126 – March 1998
Notes: For [ ] engineering units, see page 2.
Word
Bit
Description
HPC04
B04-07
RFU
ERC Enabled/Disabled Selection
B08
= 0 Ram Press/Time Pack Profiles ERC On
= 1 Ram Press/Time Pack Profiles ERC Off
B09
= 0 Cav Press/Time Pack Profiles ERC On
= 1 Cav Press/Time Pack Profiles ERC Off
B10
= 0 Ram Press/Time Hold Profiles ERC On
= 1 Ram Press/Time Hold Profiles ERC Off
B11
= 0 Cav Press/Time Hold Profiles ERC On
= 1 Cav Press/Time Hold Profiles ERC Off
B12-15
RFU
HPC05 - 08
RFU
Pack Profile Setpoints
Word
Description
HPC09
Pack Segment 1 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint after starting the Pack Profile for time period specified by HPC11.
HPC10
Pack Segment 1 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint after starting the Pack Profile for time period specified by HPC11.
HPC11
Pack Segment 1 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC09 or HPC10 for this
time period beginning with initiation of the Pack Profile.
HPC12
Pack Segment 2 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 1 for time period specified by HPC14.
HPC13
Pack Segment 2 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 1 for time period specified by HPC14.
HPC14
Pack Segment 2 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC12 or HPC13 for this
time period beginning at completion of Segment 1.
HPC15
Pack Segment 3 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 2 for time period specified by HPC17.
HPC16
Pack Segment 3 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 2 for time period specified by HPC17.
HPC17
Pack Segment 3 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC15 or HPC16 for this
time period beginning at completion of Segment 2.
HPC18
Pack Segment 4 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 3 for time period specified by HPC20.
HPC19
Pack Segment 4 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 3 for time period specified by HPC20.
HPC20
Pack Segment 4 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC18 or HPC19 for this
time period beginning at completion of Segment 3.
HPC21
Pack Segment 5 Cavity Pressure Setpoint [04] If you select Cav Press/Time profile execution, the module controls cavity pressure
to this setpoint at completion of segment 4 for time period specified by HPC23.
HPC22
Pack Segment 5 Ram (Screw) Pressure Setpoint [01] If you select Ram Press/Time profile execution, the module controls ram
(screw) pressure to this setpoint at completion of segment 4 for time period specified by HPC23.
HPC23
Pack Segment 5 Time Setpoint [21] The module controls the selected process pressure to the setpoint HPC21 or HPC22 for this
time period beginning at completion of Segment 4.
Pack Profile Offsets
Word
Description
HPC24
Pack Profile Cavity Pressure Offset [04] If you select Cav Press/Time profile execution , the module applies this entry (after reading
the sign bit) to each cavity pressure profile setpoint.
HPC25
Pack Profile Ram (Screw) Pressure Offset [01] If you select Ram Press/Time profile execution, the module applies this entry (after
reading the sign bit) to each ram (screw) pressure profile setpoint.