beautypg.com

Rockwell Automation 1771-QI,D17716.5.126 PLASTIC MOLD.MODULE User Manual

Page 94

background image

3–18

Status Word/Bit Descriptions

Publication 1771-6.5.126 – March 1998

Notes: For [ ] engineering units, see page 2.

Word

Bit

Description

SYS10

B05

Hold Profile High Cavity Pressure

B06

Pre-decompress Movement High Ram (Screw) Pressure

B07

Plastication Profile High Ram (Screw) Pressure

B08

Post-decompress Movement High Ram (Screw) Pressure

B09-15

RFU

SYS11

Overtravel Alarm Status (Latched)

Module latches alarm bits on each false-to-true transition of the corresponding real-time alarm bit in SYS07.
Module unlatches all 16 bits when it receives a false-to-true transition of DYC03-B09. You can inhibit each bit by setting
its associated alarm setpoint to zero.

This bit
latched ON:

when the module detected this alarm:

B00

Ram (Screw) Overtravel at Bottom

B01

Ram (Screw) Overtravel at Top

B02-07

RFU

B08-B15

Reserved for the module. Do not use.

SYS12

Alarm Status for Loss of Input Sensor (Latched)

Module latches alarm bits on each false-to-true transition of the corresponding real-time alarm bit in SYS08.
Module unlatches all 16 bits when it receives a false-to-true transition of DYC03-B09.

This bit
latched ON:

when the module detected this alarm

B00

Loss of Ram (Screw) Position Sensor (except when MCC64 is SET)

B01

Loss of Ram (Screw) Pressure Sensor (except when MCC64 is SET)

B02-05

RFU

B06

Loss of Screw RPM Sensor (except when MCC64 is SET)

B07

Loss of Cavity Pressure Sensor (except when MCC64 is SET)

B08-B15

RFU

SYS13

Action-execution Command Errors

B00

= 0 Normal
= 1 Jog Command Error
The module latches this bit when SYS15-B01 is RESET and one of the following is true:

S DYC01-B09 is SET

S DYC01-B10 is SET

S Y 1- 11 i T

S DYC01-B11 is SET

S DYC01-B12 is SET

S DYC01-B13 is SET

S DYC01-B14 is SET

S DYC01-B15 is SET
Module unlatches this bit when it decodes a valid DYC Block with any SET action execution bit other than listed above.

B01-04

RFU

B05

= 0 Normal
= 1 Injection Profile Command Error
The module latches this bit when both of the following are true:

S DYC02-B04 is SET

S SYS15-B08 is RESET
The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit
other than DYC02-B04.

B06

= 0 Normal
= 1 Pack Profile Command Error
The module latches this bit when both of the following are true:

S DYC02-B05 is SET

S the Injection Profile completes
The module unlatches this bit when it decodes a valid Dynamic Command Block with any SET action execution bit