CHAPTER 3 CPU ARCHITECTURE

User’s Manual U15331EJ4V1UD

67

3.3.2 Immediate addressing

[Function]

Immediate data in the instruction word is transferred to the program counter (PC) and branched.
This function is carried out when the CALL !addr16 or BR !addr16 instruction is executed.
CALL !addr16 and BR !addr16 instructions can be branched to any location in the memory space.


[Illustration]

In case of CALL !addr16 and BR !addr16 instructions

15

0

PC

8 7

7

0

CALL or BR

Low Addr.

High Addr.