CHAPTER 15 REMOTE CONTROLLER RECEIVER (

µ

PD789489, 78F9489 ONLY)

User’s Manual U15331EJ4V1UD

282

(3) Data high level width determination

Relationship Between

RMDH0S/RMDH0L/RMDH1S/RMDH1L/Counter

Position of Waveform

Corresponding Operation

Counter

< RMDH0S

<1>: Short

Error interrupt INTRERR is generated.
Measuring the guide pulse high-level width is started
at the next rising edge.

RMDH0S

≤ counter < RMDH0L

<2>: Within the range

Data 0 is received.
Measuring data low-level width is started.

RMDH0L

≤ counter < RMDH1S

<3>: Outside of the
range

Error interrupt INTRERR is generated.
Measuring the guide pulse high-level width is started
at the next rising edge.

RMDH1S

≤ counter < RMDH1L

<4>: Within the range

Data 1 is received.
Measuring the data low-level width is started.

RMDH1L

≤ counter

<5>: Long

Error interrupt INTRERR is generated at the

∆ point.

Measuring the guide pulse high-level width is started
at the next rising edge.

RIN

RMDH0S

RMDH0L

Allowable

range

<1>

<2>

<3>

RIN

RIN

RMDH1S

RMDH1L

RIN

RIN

<5>

<4>

Allowable

range