beautypg.com

3 timing – NEC PD78F9488 User Manual

Page 281

background image

CHAPTER 15 REMOTE CONTROLLER RECEIVER (

µ

PD789489, 78F9489 ONLY)

User’s Manual U15331EJ4V1UD

281

15.4.3 Timing

Operation varies depending on the positions of the RIN input waveform below.

(1) Guide pulse high level width determination

Relationship Between

RMGPHS/RMGPHL/Counter

Position of Waveform

Corresponding Operation

Counter

< PMGPHS

<1>: Short

Measuring guide pulse high-level width is started
from the next rising edge.

PMGPHS

≤ counter < PMGPHL

<2>: Within the range

INTGP is generated.
Data measurement is started.

PMGPHL

≤ counter

<3>: Long

Measuring guide pulse high-level width is started
from the next rising edge.

(2) Data low level width determination

Relationship Between RMDLS/RMDLL/Counter

Position of Waveform

Corresponding Operation

Counter

< RMDLS

<1>: Short

Error interrupt INTRERR is generated.
Measuring guide pulse high-level width is started.

RMDLS

≤ counter < RMDLL

<2>: Within the range

Measuring data high-level width is started.

RMDLL

≤ counter

<3>: Long

Measuring the end width is started from the

∆ point.

RIN

RMGPHS

RMGPHL

Allowable

range

<1>

<2>

<3>

RIN

RIN

RIN

RMDLS

RMDLL

Allowable

range

<1>

<2>

<3>

RIN

RIN