CHAPTER 18 RESET FUNCTION

User’s Manual U15331EJ4V1UD

317

Table 18-1. Status of Hardware After Reset (1/2)

Hardware

Status After Reset

Program counter (PC)

Note 1

Contents of reset
vector table (0000H,
0001H) set

Stack pointer (SP)

Undefined

Program status word (PSW)

02H

Data memory

Undefined

Note 2

RAM

General-purpose registers

Undefined

Note 2

Ports (P0 to P3, P5, P8

Note 3

) (output latches)

00H

Port mode registers (PM0 to PM3, PM5, PM8

Note 3

) FFH

Port function registers (PF7, PF8)

00H

Pull-up resistor option registers (PUB0 to PUB3)

00H

Processor clock control register (PCC)

02H

Subclock oscillation mode register (SCKM)

00H

Subclock selection register (SSCK)

Retained

Note 4

Subclock control register (CSS)

00H

Oscillation stabilization time selection register (OSTS)

04H

Timer counter (TM20)

0000H

Compare register (CR20)

FFFFH

Mode control register (TMC20)

00H

16-bit timer 20

Capture register (TCP20)

Undefined

Timer counters (TM50, TM60, TM61)

00H

Compare registers (CR50, CR60, CRH60, CR61, CRH61)

Undefined

Mode control registers (TMC50, TMC60, TMC61)

00H

8-bit timer 50, 60, 61

Carrier generator output control register (TCA60)

00H

Mode control register (WTM)

00H

Watch timer

Interrupt time selection register (WTIM)

00H

Clock selection register (WDCS)

00H

Watchdog timer

Mode register (WDTM)

00H

Serial operation mode register (CSIM20)

00H

Asynchronous serial interface mode register (ASIM20)

00H

Asynchronous serial interface status register (ASIS20)

00H

Baud rate generator control register (BRGC20)

00H

Transmit shift register (TXS20)

FFH

Serial interface 20

Receive buffer register (RXB20)

Undefined

Notes 1. While a reset signal is being input, and during the oscillation stabilization period, only the contents of the

PC will be undefined; the remainder of the hardware will be the same state as after reset.

2. In standby mode, RAM enters the hold state after reset.
3. Port 8 is used only when the port function is specified by a mask option or port function register (refer

to CHAPTER 20 MASK OPTIONS and 4.3 (3) Port function registers).

4. The register is set to 00H only by RESET input.