CHAPTER 15 REMOTE CONTROLLER RECEIVER (

µ

PD789489, 78F9489 ONLY)

User’s Manual U15331EJ4V1UD

278

Figure 15-3. Format of Remote Controller Receive Control Register (2/2)

Symbol

7 6 5 4 3 2 1 0

Address

After

reset

R/W

RMCN RMEN NCW PRSEN RMIN

0

0

RMCK1 RMCK0 FF60H 00H

R/W

RMCK1

RMCK0

Selection of source clock (f

REM

) of remote controller counter

0 0

f

X

/2

6

(625 kHz)

0 1

f

X

/2

7

(313 kHz)

1 0

f

X

/2

8

(156 kHz)

1 1

f

XT

(32.768 kHz)

Cautions 1. Always set bits 2 and 3 to 0.

2. To change the values of NCW, PRSEN, RMIN, RMCK1, and RMCK0, disable remote

controller reception (RMEN

= 0) first.

Remarks 1. f

X

: Oscillation frequency of main system clock

2. f

XT

: Oscillation frequency of subsystem clock

3. The parenthesized values apply to operation at f

X

= 4.0 MHz and f

XT

= 32.768 kHz.