CHAPTER 10 10-BIT A/D CONVERTER

User’s Manual U15331EJ4V1UD

183

(5) Timing of undefined A/D conversion result

The A/D conversion value may become undefined if the timing of the completion of A/D conversion and the
timing to stop the A/D conversion operation conflict. Therefore, read the A/D conversion result while the A/D
conversion operation is in progress. To read the A/D conversion result after the A/D conversion operation
has been stopped, stop the A/D conversion operation before the next conversion operation is completed.
Figures 10-8 and 10-9 show the timing at which the conversion result is read.

Figure 10-8. Conversion Result Read Timing (if Conversion Result Is Undefined)

End of A/D conversion

End of A/D conversion

Normal conversion result

Undefined value

Normal conversion result is read.

A/D conversion

stops.

Undefined value

is read.

ADCRL0

INTAD0

ADCS0

Figure 10-9. Conversion Result Read Timing (if Conversion Result Is Normal)

Normal conversion result

End of A/D conversion

Normal conversion

result is read.

A/D conversion stops.

ADCRL0

INTAD0

ADCS0