background image

CHAPTER 7 8-BIT TIMERS 50, 60, AND 61

User’s Manual U15331EJ4V1UD

139

Figure 7-16. Timing of Interval Timer Operation with 8-Bit Resolution

(When Timer 60 Match Signal Is Selected for Timer 50 Count Clock)

Timer 60

count clock

CR60

TCE60

INTTM60

TO60

TM60

N

00H

M

00H

00H

01H

M

N

M

00H

M

00H

00H

01H

Y

1

Y

00H

Y

00H

Y

Input clock to timer 50

(timer 60 match signal)

TO50

INTTM50

TCE50

CR50

TM50

Clear

Clear

Clear

Clear

Count start

Count start

Remark 00H

≤ N < M ≤ FFH

Y = 00H to FFH