beautypg.com

NEC PD78F9488 User Manual

Page 128

background image

CHAPTER 7 8-BIT TIMERS 50, 60, AND 61

User’s Manual U15331EJ4V1UD

128

7.3 Control Registers for 8-Bit Timers 50, 60, and 61

8-bit timers 50, 60, and 61 are controlled by the following six registers.

• 8-bit timer mode control register 50 (TMC50)
• 8-bit timer mode control register 60 (TMC60)
• Carrier generator output control register 60 (TCA60)
• 8-bit timer mode control register 61 (TMC61)
• Port mode register 3 (PM3)
• Port 3


(1) 8-bit timer mode control register 50 (TMC50)

8-bit timer mode control register 50 (TMC50) is used to control the timer 50 count clock setting and the
operation mode setting.
TMC50 is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets this register to 00H.

Figure 7-6. Format of 8-Bit Timer Mode Control Register 50 (1/2)

Symbol

<7>

<6>

5 4 3 2 1

<0>

Address

After

reset

R/W

TMC50 TCE50 TEG50 TCL502 TCL501 TCL500 TMD501

TMD500

TOE50 FF4DH

00H

R/W

TCE50

Control of TM50 count operation

Note 1

0

Clear TM50 count value and stop operation

1

Start count operation

TEG50

Selection of valid edge of TM50 count clock

0

Count at the rising edge of the count clock

1

Count at both edges of the count clock

Note 2

TCL502

TCL501

TCL500

Selection of timer 50 count clock

0 0 0

f

X

(5.0 MHz)

0 0 1

f

X

/2

3

(625 kHz)

0 1 0

f

X

/2

7

(39.1 kHz)

0 1 1

f

XT

(32.768 kHz)

1

0

0

Timer 60 match signal (INTTM60)

1

0

1

Carrier clock (in carrier generator mode) or timer 60 output signal (in other than carrier
generator mode)

Other than above

Setting prohibited

TMD501 TMD500 TMD601 TMD600

Selection of operation mode for timer 50

Note 3

0 0

×

0

Stand-alone mode (8-bit counter mode)

0 1 0 1

16-bit

counter

mode (cascade connection mode)

0 0 1 1

Carrier

generator

mode

1 0

×

0

PWM output mode

Other than above

Setting prohibited