3 control registers for serial interface 1a0 – NEC PD78F9488 User Manual
Page 219
CHAPTER 12 SERIAL INTERFACE 1A0
User’s Manual U15331EJ4V1UD
219
12.3 Control Registers for Serial Interface 1A0
Serial interface 1A0 is controlled by the following five registers.
• Serial operation mode register 1A0 (CSIM1A0)
• Automatic data transmit/receive control register 0 (ADTC0)
• Automatic data transmit/receive interval specification register 0 (ADTI0)
• Port mode register 2 (PM2)
• Port 2 (PM)
(1) Serial operation mode register 1A0 (CSIM1A0)
This register sets serial interface 1A0 serial clock, operation mode, operation enable/disable, and automatic
transmission/reception operation enable/disable.
CSIM1A0 is set via a 1-bit or 8-bit memory manipulation instruction.
RESET input sets this register to 00H.
Caution Set the port mode register 2 (PM2) in the 3-wire serial I/O mode or 3-wire serial I/O mode
with automatic transmit/receive function as follows.
• In the case of serial clock output (master transmission or master reception)
Set the SCK10/P23 pin to output mode (PM23 = 0) and clear the output latch of P23 to 0.
• In the case of serial clock input (slave transmission or slave reception)
Set the SCK10/P23 pin to input mode (PM23 = 1).
• In transmission or transmission/reception mode
Set the SO10/P24 pin to output mode (PM24 = 0) and clear the output latch of P24 to 0.
Set the SI10/P25 pin to input mode (PM25 = 1).
• In reception mode
Set the SI10/P25 pin to input mode (PM25 = 1).