CHAPTER 11 SERIAL INTERFACE 20

User’s Manual U15331EJ4V1UD

213

(c) Baud rate generator control register 20 (BRGC20)

BRGC20 is set with an 8-bit memory manipulation instruction.
RESET input sets BRGC20 to 00H.

TPS203

0

0

0

0

0

0

0

0

TPS202

0

0

0

0

1

1

1

1

f

X

/2

f

X

/2

2

f

X

/2

3

f

X

/2

4

f

X

/2

5

f

X

/2

6

f

X

/2

7

f

X

/2

8

(2.5 MHz)

(1.25 MHz)

(625 kHz)

(313 kHz)

(156 kHz)

(78.1 kHz)

(39.1 kHz)

(19.5 kHz)

TPS201

0

0

1

1

0

0

1

1

TPS200

0

1

0

1

0

1

0

1

n

1

2

3

4

5

6

7

8

Setting prohibited

Selection of baud rate generator source clock

Other than above

TPS203

TPS202

TPS201

TPS200

0

0

0

0

BRGC20

7

6

5

4

Symbol

Address

After reset

R/W

FF73H

00H

R/W

3

2

1

0

Caution When writing to BRGC20 during a communication operation, the baud rate generator

output is disrupted and communications cannot be performed normally. Be sure not to
write to BRGC20 during a communication operation.


Remarks 1. f

X

: Main system clock oscillation frequency

2. n: Values determined by the settings of TPS200 to TPS203 (1

≤ n ≤ 8)

3. The parenthesized values apply to operation at f

X

= 5.0 MHz.


If the internal clock is used as the serial clock for 3-wire serial I/O mode, set bits TPS200 to TPS203 to
set the frequency of the serial clock. To obtain the frequency to be set, use the following expression.
When an external clock is used, setting BRGC20 is not necessary.

Serial clock frequency = [Hz]

f

X

: Main system clock oscillation frequency

n: Values in the above table determined by the settings of TPS200 to TPS203 (1

≤ n ≤ 8)

f

X

2

n + 1