beautypg.com

2 adding a new wireless filter, 2 adding a new wireless filter -15, Adding a new wireless filter on – Motorola Series Switch WS5100 User Manual

Page 239

background image

Switch Security

6-15

10.Click

Cancel

to close the dialog without committing updates to the running configuration.

6.4.2 Adding a new Wireless Filter

Use the

Add

screen to create a new index and define a new address permission range. Once created, an

allow or deny designation can be applied to the new filter ACL.

To create a new filter ACL:

1. Select

Security > Wireless Filters

from the main menu tree.

2. Click the

Add

button at the bottom of the screen to launch a new dialogue used for creating an ACL.

Define an Index (numerical identifier) for the ACL and starting an ending MAC address range for the
devices allowed or denied access to the switch managed network.

3. Enter an Index numerical value (1 -1000) in the

MU-ACL Index

field.

The MU-ACL Index is a numerical identifier used to associate a particular ACL to a range of MAC
addresses (or a single MAC address) either allowed or denied access to the switch managed network.
Enter a new Index to define a new MAC Address range and allow/deny ACL Index designation.

4. Enter the a hex value for the

Starting MAC

address.

This is the beginning MAC address either allowed or denied access to the switch managed network.

5. Enter the a hex value for the

Ending MAC

address. Enter the same Starting MAC address within the

Ending MAC

field to use only the

Starting MAC

address as either allowed or denied access to the

switch managed network.

6. Use the drop-down menu to select

Allow

or

Deny

.

This rule applies to the MUs within the specified Starting and Ending MAC Address range. For example,
if the adoption rule is to Allow, access is granted for all MUs within the specified range.

7. Refer to the

Status

field for the current state of the requests made from applet. This field displays error

messages if something goes wrong in the transaction between the applet and the switch.

8. Click

OK

to use the changes to the running configuration and close the dialog.

9. Click

Cancel

to close the dialog without committing updates to the running configuration.