4.5 SERVOPACK Overload Characteristics and Allowable Load Moment of Inertia

4

SER

VOP

ACK Specifications and Dimensional Drawings

4-15

(2) Overhanging Loads

A servomotor may not be operated with an overhanging load, which tends to continuously rotate the motor. Fig.
4.1
shows a typical example of such a load.

• DO NOT use the servomotor with the Vertical Axis Motor Drive without Counterweight

• DO NOT use the servomotor with the Feeding Motor Drive

Fig. 4.1 Examples of Overhanging Loads

• Never operate servomotors with an overhanging load. Doing so will cause the SERVOPACKs’ regenerative

brake to be applied continuously and the regenerative energy of the load may exceed the allowable range
causing damage to the SERVOPACK.

• The regenerative brake capacity of the SGDH SERVOPACKs is rated for short-term operation approxi-

mately equivalent to the time it takes to decelerate to a stop.

Servomotor

Tension

Servomotor

Servomotor

Servomotor rotated repeatedly at a
constant speed to maintain the tension.

IMPORTANT