13 (2) output signals – Yaskawa Sigma II Series SGMVH User Manual

Page 138

background image

6.3 I/O Signal Connections

6

Wiring

6-13

(2) Output Signals

Notes: 1. Pin numbers in parentheses () indicate signal grounds.

2. The functions allocated to /TGON, /S-RDY, and /V-CMP (/COIN) can be changed by using the

parameters. /CLT, /VLT, /BK, /WARN, and /NEAR signals can also be changed.

Signal Name

Pin No.

Function

Reference

Common

ALM+
ALM-

31
32

Servo alarm: Turns OFF when an error is detected.

8.11.1

/TGON+
/TGON-

27
28

Detection during servomotor rotation: Detects when the servomotor is rotating
at a speed higher than the motor speed setting. Detection speed can be set by using
the parameters.

8.11.3

/S-RDY+
/S-RDY-

29
30

Servo ready: ON if there is no servo alarm when the control/main circuit power
supply is turned ON.

8.11.4

PAO
/PAO

33 (1)

34

Phase-A signal

Converted two-phase pulse (phases A and B) encoder output
signal and zero-point pulse (phase C) signal: RS-422 or the
equivalent
(Proper line receiver is SN75175 manufactured by Texas
Instruments or the equivalent corresponding to MC3486.)

8.4.6
8.5.7

PBO
/PBO

35
36

Phase-B signal

PCO
/PCO

19
20

Phase-C signal

PSO
/PSO

48
49

Phase-S signal

With an absolute encoder: Outputs serial data corresponding
to the number of revolutions (RS-422 or the equivalent)

ALO1
ALO2
ALO3

37
38

39 (1)

Alarm code output: Outputs 3-bit alarm codes.
Open-collector: 30 V and 20 mA rating maximum

8.11.1

FG

Shell

Connected to frame ground if the shield wire of the I/O signal cable is connected
to the connector shell.

Speed

/V-CMP+
/V-CMP-

25
26

Speed coincidence (output in Speed Control Mode): Detects whether the motor
speed is within the setting range and if it matches the reference speed value.

8.5.8

Position

/COIN+
/COIN-

25
26

Positioning completed (output in Position Control Mode): Turns ON when the
number of positional error pulses reaches the value set. The setting is the number of
positional error pulses set in reference units (input pulse units defined by the elec-
tronic gear).

8.6.5

Reserved

/CLT
/VLT
/BK
/WARN
/NEAR

Reserved terminals
The functions allocated to /TGON, /S-RDY, and /V-CMP (/COIN) can be changed by
using the parameters. /CLT, /VLT, /BK, /WARN, and /NEAR signals can also be
changed.

8.3.4
8.6.6
8.7.4
8.9.5

8.11.2

16
17
23
24
50

Terminals not used
Do not connect relays to these terminals.