beautypg.com

14 encoder signal converter unit, 1) model: lrx-01 / a, 2) specifications (3) dimensional drawings – Yaskawa Sigma II Series SGMVH User Manual

Page 121

background image

5 Specifications and Dimensional Drawings of Cables and Peripheral Devices

5.5.14 Encoder Signal Converter Unit

5-40

5.5.14 Encoder Signal Converter Unit

The encoder signal converter unit (the trade name “Receiver Unit”) converts encoder signal output from the line
driver to open-collector or voltage-pulse output.
A socket model 11PFA is required to use a Receiver Unit.

(1) Model: LRX-01 / A†

Contact Yaskawa Controls Co., Ltd.

(2) Specifications

(3) Dimensional Drawings

The socket is optional.

Specifications

Receiver Unit

LRX-01/A1

LRX-01/A2

LRX-01/A3

LRX-01/A4

Power Supply

12 VDC

±10 %, 100 mA

5 VDC

±5 %, 100 mA

Input Signals

Balanced line driver input (RS-422)

Output Signals

Voltage pulse
output

Open collector
output

Voltage pulse
output

Open collector
output

Input Signal
Level

Differential voltage

≥ 0.3 V, built-in terminator 100 Ω

Output Signal
Level

H: 10 V min.
(1 mA)
L: 0.5 V max.
(30 mA)

L: 0.5 V min.
(30 mA)
Withstand
voltage: 50 V

H: 3 V min.
(1 mA)
L: 0.5 V max.
(30 mA)

L: 0.5 V min.
(30 mA)
Withstand
voltage: 50 V

Surrounding Air
Temperature

0 to + 60

°C

IC Used

Receiver IC: AM26LS32C or the equivalent

Response
Frequency

100 kHz

YASKAWA

RS-422

Input Circuit

Output Circuit

Output Circuit

Output Circuit

Output Circuit

5

33.5 max.

18 max.

35.4

4

4

7.8

11-M3.5

˜7

SEMS screws

51 max.

40

r0.2

81 max.

2

Ǿ4.5 hole

50

80

35.4

129

100

Socket

Receiver unit

29

Receiver unit and socket

Socket Type 11PFA

Units: mm