8 Operation

8.4.6 Absolute Encoder Reception Sequence

8-34

Final absolute data P

M

is calculated by following formula.

(3) Detailed Signal Specifications

(a) PAO Serial Data Specifications

The number of revolutions is output in five digits.

Notes: 1. Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.

2. The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes

from “+32767” to “-32678” or from “-32678” to “+32767.” When changing multiturn limit, the
range changes. For details, refer to 8.4.7 Multiturn Limit Setting.

P

E

Current value read by encoder

P

E

= M × R + P

O

P

M

= P

E

- P

S

M

Multiturn data (rotation count data)

P

O

Number of initial incremental pulses

Use the following for reverse rotation
mode (Pn000.0 = 1).

P

E

= -M × R + P

O

P

M

= P

E

- P

S

P

S

Absolute data read at setup (This is saved and controlled by the host
controller.)
P

S

= M

S

× R + P

S

'

M

s

Multiturn data read at setup

P

S

'

Number of initial incremental pulses read at setup

P

M

Current value required for the user’s system.

R

Number of pulses per encoder revolution (pulse count after dividing,
value of Pn201)

Coordinate

value

Value M

Reference position (setup)

- 1

0

+1

+2

+3

+3

Current position

+2

+1

0

P

E

P

M

P

S

P

O

M

×R

Data Transfer Method

Start-stop Synchronization (ASYNC)

Baud rate

9600 bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

8 characters, as shown below.

Data

Start bit

Even parity

"+" or "- "

"0" to "9"

"CR"

"P"

Stop bit

0 0 0 0 0 1 0 1 0 1