beautypg.com

5 absolute encoder setup (fn008), Important – Yaskawa Sigma II Series SGMVH User Manual

Page 213

background image

8 Operation

8.4.5 Absolute Encoder Setup (Fn008)

8-32

8.4.5 Absolute Encoder Setup (Fn008)

Setting up (initializing) the absolute encoder is necessary in the following cases.

• When starting the machine for the first time
• When an encoder backup error alarm (A.81) is generated
• When an encoder checksum error alarm (A.82) is generated
• When the multiturn data of the absolute encoder is to be 0.

Use a built-in type digital operator in the SERVOPACK or a digital operator for setup.

1. Encoder setup operation is only possible when the servo is OFF.
2. If the following absolute encoder alarms are displayed, cancel the alarm by using the same method as the

setup (initializing). They cannot be canceled with the SERVOPACK alarm reset input signal (/ALM-
RST).
• Encoder backup error alarm (A.81)
• Encoder checksum error alarm (A.82)
Any other alarms that monitor the inside of the encoder should be canceled by turning OFF the power.

IMPORTANT

Step

Display after

Operation

Digital

Operator

Panel

Operator

Description

1

Alarm generated

2

Press the DSPL/SET or MODE/SET Key to select the utility func-
tion mode.

3

Press the UP or DOWN Key to select parameter Fn008.
Note: The digit that can be set will blink.

4

Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second.
The display will be as shown at the left.

5

Continue pressing the UP Key until PGCL5 is displayed.
Note: If there is a mistake in the key operation, “nO_OP” will

blink for about one second. The panel operator or digital
operator will return to the utility function mode.

6

Press the DSPL/SET or MODE/SET Key. This will clear the mul-
titurn data of the absolute encoder.
When completed, “donE” will blink for about one second.

7

About one second later

After “donE” is displayed, “PGCL5” will be displayed again.

8

Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second to return to the Fn008 display of the utility
function mode.

9

Turn OFF the power, and then turn it ON again to make the setting valid.

(DSPL/SET Key)

DSPL

SET

MODE/SET

(MODE/SET Key)

(DATA/ENTER Key)

DATA

ENTER

DATA/

(DATA/SHIFT Key)

(Press at least 1 s.)

(DSPL/SET Key)

DSPL

SET

MODE/SET

(MODE/SET Key)

(DATA/ENTER Key)

DATA

ENTER

DATA/

(DATA/SHIFT Key)

(Press at least 1 s.)