beautypg.com

1 overload characteristics – Yaskawa Sigma II Series SGMVH User Manual

Page 72

background image

4 SERVOPACK Specifications and Dimensional Drawings

4.5.1 Overload Characteristics

4-12

4.5 SERVOPACK Overload Characteristics and Allowable Load

Moment of Inertia

4.5.1 Overload Characteristics

SERVOPACKs have a built-in overload protective function that protects the SERVOPACKs and servomotors
from overload. Allowable power for the SERVOPACKs is limited by the overload protective function as shown
in the figure below.

The overload detection level is set under hot start

1

conditions at a servomotor surrounding air temperature of

40

°C.

1

Hot Start

A hot start indicates that both the SERVOPACK and the servomotor have run long enough at the rated load to be thermally
saturated.

TERMS

Operating time (s)

Rated current

Maximum current

Motor current

Approx.

Rated current

+

Maximum current

2

10000

1000

100

5

1

10000

1000

100

5

1

10000

1000

100

10

5

1

10000

1000

100

10

5

1