7.3 Operation in Parameter Setting Mode (Pn†††)

7

Digital Operator/Panel Operator

7-21

7.3 Operation in Parameter Setting Mode (Pn†††)

Functions can be selected or adjusted by setting parameters. There are two types of parameters. One type requires
value setting and the other requires function selection. These two types use different setting methods.

With value setting, a parameter is set to a value within the specified range of the parameter. With function selec-
tion, the functions allocated to each digit of the seven-segment LED panel indicator (five digits) can be selected.

7.3.1 Setting Parameters

(1) Value Setting Parameters

(a) Types of Value Setting Parameters

Refer to 11.3.2 List of Parameters.

(b) Example of Changing Value Setting Parameter

The parameter settings can be used for changing parameter data. Before changing the data, check the permit-
ted range of the parameter.

The example below shows how to change parameter Pn100 (speed loop gain) from “40” to “100.”

EXAMPLE

Step

Display after

Operation

Digital Operator

Panel Operator

Description

1

Press the DSPL/SET or MODE/SET Key to select the
parameter setting mode. If a parameter other than
Pn100 is displayed, press the UP or DOWN Key to
select Pn100.

Note: The enabled digit blinks.

2

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The current data of
Pn100 is displayed.

3

Press the LEFT or RIGHT Key or DATA/SHIFT Key to
select the digit to be set.

4

Press the UP or DOWN Key to change the data.
Keep pressing UP or DOWN Key until “00100” is dis-
played.

5

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The value blinks and is
saved.

6

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the display of
Pn100. The data for the speed loop gain (Pn100) is
changed from “40” to “100.”

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

DATA/

(DATA/SHIFT Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)