9.5 Analog Monitor

9

Adjustments

9-21

(1) Related Parameters

The following signals can be monitored.

(a) Pn003: Function Selections

* When using speed control or torque control, the position error monitor signal is not specified.

The analog monitor output voltage is ±8 V (maximum). The output will be limited to ±8 V even if this value is exceeded
in the above calculations.

Parameter

Function

Monitor 1

Monitor 2

Monitor Signal

Observation Gain

Remarks

Pn003

n.†††0

n.††0†

Motor speed

1 V / 1000 min

-1

Factory setting for Monitor 1

n.†††1

n.††1†

Speed reference

1 V / 1000 min

-1

n.†††2

n.††2†

Internal torque reference

1 V / 100% rated torque

Factory setting for Monitor 2

n.†††3

n.††3†

Position error

0.05 V / 1 reference unit

n.†††4

n.††4†

Position error

0.05 V / 100 reference units

n.†††5

n.††5†

Position reference speed
(converted to motor speed)

1 V / 1000 min

-1

n.†††6

n.††6†

Motor speed

1 V / 250 min

-1

n.†††7

n.††7†

Motor speed

1 V / 125 min

-1

n.†††8

n.††8†

Reserved. Do not set.

n.†††9

n.††9†

n.†††A

n.††A†

n.†††B

n.††B†

n.†††C

n.††C†

n.†††D

n.††D†

n.†††E

n.††E†

n.†††F

n.††F†