beautypg.com

18 fully-closed application module – Yaskawa Sigma II Series SGMVH User Manual

Page 125

background image

5 Specifications and Dimensional Drawings of Cables and Peripheral Devices

5.5.18 Fully-closed Application Module

5-44

5.5.18 Fully-closed Application Module

(1) Model: JUSP-FC100

(2) Specifications

(3) Dimensional Drawings

Item

Details

Applicable SERVOPACK

All SGDH-†††EB models

Installation Method

Mounted on the SGDH SERVOPACK side: CN10.

Basic
Specifications

Power Supply Method

Supplied from the SERVOPACK control power supply.

Power Consumption

0.5 W or less

Fully Closed
System
Specifications

Fully-closed Encoder Pulse
Output Form

5 V differential line-driver output (complies with EIA Standard
RS-422A)

Fully-closed Encoder Pulse
Signal Form

90

°

Phase difference 2-phase differential pulse (phase A, phase B)

Maximum Receivable Fre-
quency for SERVOPACK

1 Mbps

Power Supply for Fully-
closed Encoder

To be prepared by customer.

Internal Functions

Protection

Detecting fully-closed encoder disconnection

LED Indicators

Setting with the parameters

128

(24)

CN4

142

(100)

20

FC100

Nameplate

M4

Units: mm
Approx. mass: 0.2 kg

FG terminal

Connector

To SERVOPACK