11.4 Parameter Recording Table

11-29

11

Appendix

11.4 Parameter Recording Table

Use the following table for recording parameters.

Note: Setting validation (“immediately” or “after restart”) for Pn10B differs depending on the digit. The digits vali-

dated after restart are underlined in “Factory Setting” column.

Parameter

No.

Factory

Setting

Name

Setting

Validation

Pn000

0000

Function Selection Basic Switches

After restart

Pn001

0000

Function Selection Application
Switches 1

After restart

Pn002

0000

Function Selection Application
Switches 2

After restart

Pn003

0002

Function Selection Application
Switches 3

After restart

Pn004

0000

Reserved (Do not change)

Immediately

Pn005

0000

Reserved (Do not change)

Immediately

Pn100

40 Hz

Speed Loop Gain

Immediately

Pn101

20.00 ms

Speed Loop Integral Time Constant

Immediately

Pn102

40 /s

Position Loop Gain

Immediately

Pn103

0%

Moment of Inertia Ratio

Immediately

Pn104

40 Hz

2nd Speed Loop Gain

Immediately

Pn105

20.00 ms

2nd Loop Integral Time Constant

Immediately

Pn106

40 /s

2nd Position Loop Gain

Immediately

Pn107

0 min

-1

Bias

Immediately

Pn108

7 reference

units

Bias Width Addition

Immediately

Pn109

0%

Feed-forward

Immediately

Pn10A

0.00 ms

Feed-forward Filter Time Constant

Immediately

Pn10B

0000

Gain-related Application Switches

After restart
/Immediately

Pn10C

200%

Mode Switch Torque Reference

Immediately

Pn10D

0 min

-1

Mode Switch Speed Reference

Immediately

Pn10E

0 min

-1

/s

Mode Switch Acceleration

Immediately

Pn10F

0 reference

units

Mode Switch Error Pulse

Immediately

Pn110

0012

Online Autotuning Switches

After restart

Pn111

100

Speed Feedback Compensation

Immediately

Pn112

100%

Reserved (Do not change)

Immediately

Pn113

1000

Reserved (Do not change)

Immediately

Pn114

200

Reserved (Do not change)

Immediately

Pn115

32

Reserved (Do not change)

Immediately

Pn116

16

Reserved (Do not change)

Immediately

Pn117

100%

Reserved (Do not change)

Immediately

Pn118

100%

Reserved (Do not change)

Immediately

Pn119

50 /s

Reserved (Do not change)

Immediately

Pn11A

1000%

Reserved (Do not change)

Immediately

Pn11B

50 Hz

Reserved (Do not change)

Immediately

Pn11C

70 Hz

Reserved (Do not change)

Immediately

Pn11D

100%

Reserved (Do not change)

Immediately

Pn11E

100%

Reserved (Do not change)

Immediately

Pn11F

0 ms

Reserved (Do not change)

Immediately

Pn120

0 ms

Reserved (Do not change)

Immediately

Pn121

50 Hz

Reserved (Do not change)

Immediately