beautypg.com

Yaskawa Sigma II Series SGMVH User Manual

Page 326

background image

11 Appendix

11.3.2 List of Parameters

11-24

„

Input signal polarities

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Pn50B

Input Signal Selections 2

6543

After restart

0

1

2

3

4

5

6

7

8

9

A

B

Reverse run allowed when CN1-40 input signal is ON (L-level).

Reverse run allowed when CN1-41 input signal is ON (L-level).

Reverse run allowed when CN1-42 input signal is ON (L-level).

Reverse run allowed when CN1-43 input signal is ON (L-level).

Reverse run allowed when CN1-44 input signal is ON (L-level).

Reverse run allowed when CN1-45 input signal is ON (L-level).

Reverse run allowed when CN1-46 input signal is ON (L-level).

Reverse run prohibited.

Reverse run allowed.

Reverse run allowed when CN1-40 input signal is OFF (H-level).

Reverse run allowed when CN1-41 input signal is OFF (H-level).

Reverse run allowed when CN1-42 input signal is OFF (H-level).

0 to F Same as above

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

Reverse run allowed when CN1-43 input signal is OFF (H-level).

Reverse run allowed when CN1-44 input signal is OFF (H-level).

Reverse run allowed when CN1-45 input signal is OFF (H-level).

Reverse run allowed when CN1-46 input signal is OFF (H-level).

C

D

E

F

/P-CL Signal Mapping (Forward Torque Limit when ON (L-level))

0 to F Same as above

/N-CL Signal Mapping (Reverse Torque Limit when ON (L-level))

N-OT Signal Mapping (Overtravel when OFF (H-level))

/ALM-RST Signal Mapping (Alarm Reset when ON (L-level))

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

ON when CN1-40 input signal is ON (L-level).

ON when CN1-41 input signal is ON (L-level).

ON when CN1-42 input signal is ON (L-level).

ON when CN1-43 input signal is ON (L-level).

ON when CN1-44 input signal is ON (L-level).

ON when CN1-45 input signal is ON (L-level).

ON when CN1-46 input signal is ON (L-level).

Sets signal ON.

Sets signal OFF.

ON when CN1-40 input signal is OFF (H-level).

ON when CN1-41 input signal is OFF (H-level).

ON when CN1-42 input signal is OFF (H-level).

ON when CN1-43 input signal is OFF (H-level).

ON when CN1-44 input signal is OFF (H-level).

ON when CN1-45 input signal is OFF (H-level).

ON when CN1-46 input signal is OFF (H-level).

Signal

Effective Level

Voltage level

Contact

ON

Low (L) level

0 V

Close

OFF

High (H) level

24 V

Open

INFO